Victoria Shed Regulations (Permit, Size, Setbacks)

Building a backyard shed in Victoria, BC is mostly a question of size and location. The City of Victoria doesn’t require a building permit for an accessory building under 10 m² (108 square feet), but the shed still has to follow the zoning rules for height, setbacks and placement. This page sets out what the City’s bylaws say for single-family lots, with the clause numbers so each figure can be checked.

Permit-free under10 m²108 square feet of building area. Building and Plumbing Regulation Bylaw 17-113, s.5(2)(f).
Permit needed at10 m² or more108 square feet or larger. The permit fee is a $100 application fee plus 1.40% of construction cost.
Max height3.5 m11.5 feet. Zoning Regulation Bylaw Schedule F, s.3(a). Roof decks aren’t allowed.
Rear setback0.6 m2 feet from the rear lot line. Schedule F, s.4(a).
Side setback0.6 m2 feet from an interior side lot line. Schedule F, s.4(b).
Front yard ruleRear yard onlyAccessory buildings must be in the rear yard. Schedule F, s.1.

Quick answer: do you need a permit for a shed in Victoria?

  • No building permit is needed for an accessory building with a building area under 10 m² (108 square feet).
  • A shed of 10 m² or more needs a building permit, and the maximum size under zoning is 37 m² (398 square feet).
  • Permit or not, the shed must sit in the rear yard, at least 0.6 m (2 feet) from the lot lines and 2.4 m (7.9 feet) from the house.
CITY RULES (RESIDENTIAL ZONES):
BylawsZoning Regulation Bylaw 80-159, Schedule F (Accessory Building Regulations). Building and Plumbing Regulation Bylaw 17-113.
Permit exemptionBylaw 17-113, s.5(2)(f): the bylaw doesn’t apply to “accessory buildings with a building area of less than 10 square meters.”
How area is measuredThe bylaw uses “building area” as defined in the BC Building Code (Bylaw 17-113, s.2(1)). Schedule F s.2(a) measures the size cap by floor area of all levels combined.
Use limitsSchedule F, s.6(a): no dwelling use, no shower, bath or toilet, and no more than one plumbing fixture that needs drainage (unless the zone allows a dwelling).
Maximum size37 m² (398 square feet) of floor area (Schedule F, s.2(a)). Rear yard coverage is capped at 25% (s.5(b)). Overall zone site coverage also applies (s.5(a)).
Maximum height3.5 m (11.5 feet) (Schedule F, s.3(a)). Roof decks aren’t permitted (s.3(b)). Schedule F gives one height for all roof types.
Rear setback0.6 m (2 feet) (Schedule F, s.4(a)).
Interior side setback0.6 m (2 feet) (Schedule F, s.4(b)).
Corner lot (flanking street) setback3.5 m (11.5 feet), or the minimum front setback of the adjoining lots, whichever is greater (Schedule F, s.4(c)).
Front yardNot allowed. Accessory buildings must be located in the rear yard (Schedule F, s.1).
Separation from the house2.4 m (7.9 feet) (Schedule F, s.4(d)). Eaves may project up to 0.75 m (2.5 feet) into a setback (s.4(e)).
Zones coveredSchedule F applies in zones that refer to it, such as R1-B (Part 1.2, s.1.2.1(d)). The RS-1 zone (Part 1.42, s.8) has its own rules: 3 m (10 feet) maximum height, 30% of the rear yard maximum, 2.4 m (7.9 feet) from the house. Panhandle lots follow Schedule H. Other zones weren’t checked.
Permit fee (if needed)$100 application fee plus 1.40% of the cost of construction (Bylaw 17-113, Schedule A). No separate shed fee is published.

What the BC Building Code says

BCBC 2024 Division A 1.1.1.1(2)(e) says the Code doesn’t apply to accessory buildings less than 10 m² in building area that don’t create a hazard. “Hazard” isn’t defined, so the local building official decides, and where a city’s own documents are silent the provincial rule is the default, though a city may be stricter. The 10 m² figure on this page comes from the City of Victoria’s own Bylaw 17-113, s.5(2)(f), which doesn’t repeat the hazard wording, and the size, height and setback figures come from the City’s Zoning Regulation Bylaw.

Rules that apply even without a building permit

What isn’t confirmed

  • The exact City wording for how “building area” is measured isn’t set out in the bylaws reviewed.
  • How height is measured on a pitched roof isn’t stated in Schedule F.
  • Whether the City wants a site plan or zoning check for a shed that doesn’t need a permit isn’t published.
  • For RS-1 lots, the rear and side setbacks for sheds weren’t found, and a lane setback wasn’t found for any zone.
  • Zones other than R1-B and RS-1 weren’t checked, and the City publishes no shed-specific fee or handout.

Who to contact

City of Victoria Permits and Inspections: 250-361-0344. Development Services (zoning questions): 250-361-0536. Official documents used:

Frequently asked questions

How big can a shed be in Victoria without a permit?

Under 10 m² (108 square feet) of building area. At 10 m² or more, a building permit is required.

Can a shed go in the front yard in Victoria?

No. Schedule F, s.1 says accessory buildings must be located in the rear yard.

How close to the fence can a shed be?

In zones that use Schedule F, 0.6 m (2 feet) from the rear and interior side lot lines. On a corner lot, the street side needs at least 3.5 m (11.5 feet). RS-1 lots follow different rules, so they need a check with the City.

Can a Victoria shed have a bathroom?

Not under Schedule F, s.6. It bars showers, baths and toilets, and allows only one drained plumbing fixture, unless the zone expressly permits a dwelling use.

For the province-wide picture, see Maximum Shed Size Without a Permit in BC and Shed Rules by City.

The figures on this page are a general guide, checked 26 October 2026. Confirm them with the City of Victoria before building.